Search results for "Metering mode"
showing 10 items of 22 documents
A new PLC-based smart metering architecture for medium/low voltage grids: Feasibility and experimental characterization
2018
Abstract This paper investigates the feasibility of a smart metering architecture for modern power grids in the smart cities framework. A particular focus is made on Automatic Meter Reading, with the aim of facing some costs and safety drawbacks of current solutions (such as dependence from wireless communication providers, reliability problems in bad weather conditions, and exposition to cyber-attacks). The proposed architecture exploits power line communications (PLC) at both low and medium voltage level, thanks to new devices and an innovative medium voltage PLC coupling system. The new coupling solution and the whole smart metering architecture are experimentally verified in a wide freq…
Characterization of DC series arc faults in PV systems based on current low frequency spectral analysis
2021
Abstract This work presents an experimental study focused on the characterization of series arc faults in direct current (DC) photovoltaic (PV) systems. The aim of the study is to identify some relevant characteristics of arcing current, which can be obtained by means of low frequency spectral analysis of current signal. On field tests have been carried out on a real PV system, in accordance with some tests requirements of UL 1699B Standard for protection devices against PV DC arc faults. Arcing and non-arcing current signals are acquired and compared and the behavior of a set of indicators proposed by authors is analyzed. Different measurement equipment have been used, in order to study th…
On the Non-Intrusive Load Monitoring in dwellings: a feasibility perspective
2021
The oncoming modernization process of the power grids, driven above all by decarbonisation objectives and the continuous improvement of digital technologies, is encouraging active participation in the electricity market by consumers through the Demand-Response mechanism. From this perspective, the introduction of smart meters and energy consumption monitoring devices plays a fundamental role, being able to give benefits to consumers, suppliers and the electricity grid itself. This paper proposes a supervised method of non-intrusive load monitoring (NILM) based on the recognition of patterns in the time domain with the Dynamic Time Warping algorithm which is suitable for low-cost smart meter…
Capacity and safety analysis of hard-shoulder running (HSR). A motorway case study
2016
Abstract Operational motorway conditions can be improved by introducing traffic flow management and control systems, such as ramp metering (RM), high occupancy vehicle (HOV) lanes, real-time variable speed limits (VSLs), reversible lanes (RL), automated highway systems (AHS) and hard-shoulder running (HSR). The effects of such devices need to be examined in terms of capacity and safety. This paper examines the case study of the Italian motorway A22, which is supposed to be equipped with an HSR system implemented along 128 km in order to reduce congestion with consequent improvement in levels of service (LOS). We studied the traffic processes (capacity, flow distribution between lanes, relia…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
A composite indicator for water meter replacement in an urban distribution network
2012
In water supply management, volumetric water meter are typically used to measure users' consumption. With water meters, utilities can collect useful data for billing, assess the water balance of the system, and identify failures in the network, water theft and anomalous user behaviour. Despite their importance, these instruments are characterised by intrinsic errors that cause so-called apparent losses. The complexity of the physical phenomena associated with metering errors in aging water meters does not allow meter replacement to be guided by single parameters, such as the meter age or the total volume passed through the meter. This paper presents a meter replacement strategy based on a c…
A simple unsynchronized two‐end algorithm for faults location and identification in electrical distribution systems
2012
PurposeThe purpose of this paper is to identify a new and simple two‐end algorithm for fault location identification and characterization, in electrical distribution systems.Design/methodology/approachThe developed diagnostic algorithm is based on a simple model of the network using a lumped parameters representation.FindingsTest results have proved the approach to be efficient, allowing a precise fault identification and location while not requiring synchronized measures from the two ends.Research limitations/implicationsThere is a need for measurement systems at all MV/LV substations.Practical implicationsApplicability with limited investments is not possible where metering systems are no…
The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion
2007
For the electricity metering for billing purposes in distribution systems, the static meters are substituting the traditional inductive meters. Thus, the evaluation of the performances of such equipments is required, also in the presence of disturbances affecting the power systems. With respect to this, this paper analyzes the main aspects related to the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Particular attention is given to the reference standard meters, that are not considered by the actual in-force Standards. The analysis is supported by several experimental tests.
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…
Active power analog front-end based on a Wheatstone-type magnetoresistive sensor
2011
Abstract In the proposed work a practical magnetoresistive wattmeter based on a commercial sensor is designed to measure active power at industrial frequencies. The electronic conditioning circuit uses differential blocks in order to preserve the sensor initial common mode rejection ratio. A 700 W power level has been reached with an uncertainty less than 1%. With few changes the proposed circuitry could be used in metering applications.